Wind mitigation · Palm Beach County

Wind Mitigation Inspection in Palm Beach County: How the Form Works North of the HVHZ

A county guide for Palm Beach County owners: why the wind mitigation form reads differently outside the High-Velocity Hurricane Zone, what local homes, condos and 55+ communities tend to show, where the permits are and how to prepare.

  • Updated
  • 22 min read
  • Based on form OIR-B1-1802 (Rev. 04/26), the Florida Building Code and Palm Beach County building information
Inspector on a ladder checking the edge of a flat concrete tile hip roof on a Mediterranean-style home in Palm Beach County

The short answer

A wind mitigation inspection in Palm Beach County records your home's hurricane features on Florida's uniform form, OIR-B1-1802, so your insurer can apply the windstorm credits state law requires it to offer. The form is the same statewide, but this county sits outside the High-Velocity Hurricane Zone. The Region answer is looked up for each address, the 1994 South Florida code option does not exist here, and most older homes earn their credits from the roof, the attic connections and protected openings.

Key points

  • The Florida Building Code limits the HVHZ to Broward and Miami-Dade. Palm Beach County is outside it.
  • Item 2 on a Palm Beach County form is Region 1, 2 or 3, taken from the design wind speed at your address.
  • Homes permitted before March 1, 2002 cannot use the building code item, so the roof, attic and openings carry the report.
  • Condo boards and HOAs must adopt hurricane protection specifications and cannot refuse a conforming upgrade.
  • The report can stay valid for up to five years. Your insurer, not the inspector, decides what each answer is worth.
In this article 14 sections
  1. What a wind mitigation inspection in Palm Beach County covers
  2. Palm Beach County is outside the High-Velocity Hurricane Zone
  3. Which building code built your Palm Beach County home?
  4. The wind-borne debris region and opening protection in Palm Beach County
  5. What homes across Palm Beach County tend to show on the form
  6. Condos, HOAs and 55+ communities: association records and board specifications
  7. Wind mitigation and insurance in Palm Beach County: what the law and Citizens say
  8. Wind mitigation inspections in Boca Raton, Delray Beach, Boynton Beach and West Palm Beach
  9. Finding permits in Palm Beach County: city or county?
  10. How to prepare for a wind mitigation inspection in Palm Beach County
  11. Upgrades that move a Palm Beach County wind mitigation report
  12. What older advice about Palm Beach wind mitigation got wrong
  13. How much does a wind mitigation inspection cost in Palm Beach County?
  14. The bottom line

What a wind mitigation inspection in Palm Beach County covers

A wind mitigation inspection in Palm Beach County is a short visit that turns the way your house was built into evidence your insurer can use. The inspector works through the nine items of the Uniform Mitigation Verification Inspection Form, OIR-B1-1802 (Rev. 04/26): building code, region, roof slope, roof covering, roof deck attachment, roof-to-wall attachment, roof geometry, secondary water resistance and opening protection. From item 2 onward, every attribute marked on the form needs a photo or a document behind it. You send the signed form to your agent, and the insurer decides which credits it earns.

Nobody can make you order one. Section 627.0629 of the Florida Statutes requires residential rate filings to include actuarially reasonable discounts, credits or other rate differentials for windstorm mitigation features, and Section 627.711 obliges insurers to tell you about them when a policy is written and again at each renewal. The catch is simple: a carrier has no way to credit straps, a hip roof or rated windows it has no record of. Our plain-English explanation of wind mitigation covers the idea behind those credits, and the guide to how the inspection visit works goes through the form item by item.

This page is about what changes once you cross the Hillsboro Canal heading north: the code zone, the building history, the kinds of communities, the paperwork and the associations that control much of it. If you own property on the Broward side too, that county plays by different rules, and our article on wind upgrades for Hollywood homes covers that side of the line.

Palm Beach County is outside the High-Velocity Hurricane Zone

The Florida Building Code defines the High-Velocity Hurricane Zone in a single sentence: "This zone consists of Broward and Miami-Dade counties." Palm Beach County is not part of it. The HVHZ is less a weather boundary than a separate block of code sections, carried into the statewide code from the old South Florida Building Code, that switches on only below the county line.

Two practical differences follow from that. The first is how wind speed is set. Inside the HVHZ, Section 1620.2 gives each county one fixed design wind speed per risk category; for an ordinary house, which is Risk Category II, that is 170 mph in Broward and 175 mph in Miami-Dade. North of the line, wind speeds come from contour maps that change with location. The Palm Beach County Building Division publishes its own ultimate design wind speed maps and a separate GIS tool for each risk category, because, as the county explains, the contour lines do not follow roads or canals closely enough to describe them any other way.

The second difference is the building envelope. The HVHZ sections require exterior walls, the roof, outside doors, windows, skylights and glass block to meet impact test criteria or be covered by a device that does. In Palm Beach County, protection for glazed openings comes instead from the statewide wind-borne debris rules, which the next sections explain.

What that changes on the wind mitigation form

The form includes a few answers written only for the HVHZ, and a Palm Beach County report should not use any of them:

  • Item 1, Building Code. The 1994 South Florida Building Code answer (SFBC-94) is reserved for HVHZ homes. Here, a house answers FBC 2001 and 2004, FBC 2007 or later, or neither, depending on when its permit was applied for.
  • Item 2, Region. HVHZ is not an option. The answer is Region 1 (140 mph or more), Region 2 (130 to 139 mph) or Region 3 (below 130 mph), read from the ASCE 7-22 hazard tool for the specific address.
  • Item 4, Roof Covering. The B answer includes a path for HVHZ roofing permits applied for between 1994 and 2002. That path does not exist in this county, although a Miami-Dade product approval still counts anywhere in Florida.

The other six items use identical definitions in all three South Florida counties. The deck nailing, the straps, the roof shape, the water barrier and the openings are graded the same way, and items 5, 6 and 9 are still decided by the weakest example on the house.

Broward and Miami-Dade (HVHZ) compared with Palm Beach County
Broward and Miami-Dade (HVHZ)Palm Beach County
Code zoneHigh-Velocity Hurricane Zone sections of the Florida Building CodeOutside the HVHZ; the statewide wind provisions apply
Design wind speedOne fixed speed per county and risk category (Section 1620.2)Varies by location; the county publishes maps and a GIS tool for each risk category
Opening protection in the codeThe whole envelope must meet impact test criteria or be protected (Section 1626)Glazed openings in the wind-borne debris region must be impact resistant or protected (Section 1609.1.2)
Item 1, Building CodeFBC 2001 and 2004, FBC 2007 or later, or SFBC-94FBC 2001 and 2004 or FBC 2007 or later only
Item 2, RegionAlways HVHZRegion 1, 2 or 3 from the ASCE 7-22 hazard tool
Item 4, Roof CoveringIncludes a path for HVHZ roofing permits from 1994 to 2002No HVHZ permit path; Miami-Dade approvals still count
Items 3 and 5 to 9Same definitions statewideSame definitions statewide
Citizens opening protection credit for buildings of 4+ stories built 2002 or laterListed for Miami-Dade and BrowardNot listed; ask your agent how openings are credited

Which building code built your Palm Beach County home?

The statewide Florida Building Code took effect on March 1, 2002. Before then, each region followed a model code of its own. A Florida House analysis of the 2000 bill that put the statewide code in place summed up the map: Dade and Broward used amended versions of the South Florida Building Code, and the Standard Building Code had been adopted by the remaining 65 counties and most cities in them. Palm Beach County was one of those 65. The same analysis named the most significant difference between the codes: the wind-borne debris standards of the South Florida code, which had been strengthened after Hurricane Andrew.

That history explains a pattern we see on reports from this county. A Broward house permitted in 1996 went up when its county already required debris-resistant construction, and it may answer SFBC-94 on item 1. A Palm Beach County house from the same year was built under a different code, has no SFBC-94 answer available, and often still has its original glass unless shutters or impact windows were added later. For any house here permitted before March 2002, the building code item will not help, and the result rests on items 3 through 9.

Homes permitted on or after March 1, 2002 can answer item 1, subject to the permit dates the form sets for houses finished in 2002 or 2003 and in 2007 or 2008. Even then, the other eight items are documented one at a time, and a 2010 house can still come back unknown on the deck nailing or the water barrier if nobody can see or prove them.

Palm Beach County homes by permit era and what usually decides the form (a starting point, not proof)
Permit eraWhat you often findWhat usually decides the report
Before the 1960sOlder houses in coastal towns and historic districts, often with later additionsRoof shape, any connectors added since and whether the openings were ever protected
1960s and 1970sRanch homes near the Intracoastal, early condo buildings and the first large 55+ condo communitiesAttic access, roof-to-wall connections and the association's roof and window records
1980s to early 2002Planned and gated communities west of I-95, mostly built under the Standard Building CodeRoof geometry on Mediterranean designs, strap type, re-roof permits and opening upgrades
Permits from March 1, 2002 to 2006Homes built under the first editions of the Florida Building CodeItem 1 can apply with the right permit date; the deck and the water barrier still need proof
Permits from 2007 onNewer subdivisions, infill rebuilds and recent condo buildingsProduct approvals for every opening and the roofing documents

Use the table to set expectations, not to predict a result. Additions, re-roofs and window projects change houses one at a time, and the attic often tells a different story from the year listed on the property appraiser's record.

Aerial view of a gated Palm Beach County community with concrete tile roofs, gable ends, entry towers, pools and a golf course
Fig. 01Mediterranean designs often mix hip roofs with gable ends and towers, which is why item 7 is measured, not guessed.

The wind-borne debris region and opening protection in Palm Beach County

Outside the HVHZ, the code's rules for windows and doors depend on the wind-borne debris region. Palm Beach County's Building Division defines it as the parts of a hurricane-prone region that lie within one mile of the coastal mean high water line where the ultimate design wind speed is 130 mph or more, or anywhere that speed reaches 140 mph or more. Interpolating between contour lines is not allowed when drawing it. The county also states plainly that all of unincorporated Palm Beach County lies inside the wind-borne debris region. If your house is inside one of the cities, that city's building department applies the same definition to your lot.

Inside the region, Section 1609.1.2 of the Florida Building Code requires glazed openings to be impact resistant or covered by an impact-resistant protective system, with garage and rolling doors tested to ANSI/DASMA 115. For one- and two-family homes with a mean roof height of 33 feet or less, the code also allows wood structural panels at least 7/16 inch thick, cut and fastened as it specifies. These rules govern new installations and replacements under a permit. They do not reach back and require an older house to add protection, which is why a home permitted before 2002 can still have unprotected openings somewhere.

Product approvals: what the inspector needs to see

Windows, doors, shutters and garage doors installed under a Florida permit usually carry either a Florida Product Approval or a Miami-Dade Notice of Acceptance (NOA). Products with a Miami-Dade approval are installed in this county as well, but a statewide approval for use outside the HVHZ can be the correct choice here. For the form, the brand matters less than the proof. Item 9 asks which impact standard each opening meets, so the inspector needs a permanent label, an etched mark, a permit or an approval document that ties the product to that standard. Protection nobody can verify is graded N, however solid it looks.

One weak opening still decides the item. A house with rated windows and an old garage door, or with impact glass everywhere except a small bathroom window, is graded by that one opening. Our guide to impact windows, shutters and garage doors explains each opening protection level and the standards behind it.

White accordion hurricane shutters partly closed over an arched window on a stucco Mediterranean-style home in Palm Beach County
Fig. 02Shutters count on item 9 only when they can be tied to a tested standard by a label, a permit or an approval document.

What homes across Palm Beach County tend to show on the form

The county runs from the Broward line to Martin County and from the ocean to Lake Okeechobee, and its housing changes as you move west. These are the property types we see most often, and the items that usually decide their reports.

Type01

Coastal towns and the Intracoastal

Along the barrier island and the Intracoastal, from Boca Raton and Delray Beach north to Palm Beach and Jupiter, houses range from pre-war cottages to rebuilt waterfront estates. Older ones often combine barrel tile over gable sections, additions from several decades and openings upgraded in stages. Salt is the other factor. Roof-to-wall connectors only count when they are free of visible severe corrosion, and shutter tracks and anchors close to the water age faster than the same hardware a few miles inland.

What usually decides it
The weakest strap along the attic perimeter, and the oldest opening
Have ready
Permits for each addition and each window or shutter job

Type02

Inland planned and gated communities

West of I-95 and out toward the Turnpike, much of the county was developed as planned communities of block homes with wood trusses and concrete tile roofs, many of them permitted before 2002. Mediterranean styling adds gable ends, entry towers and flat sections behind parapets, any of which can push a roof out of the hip answer on item 7 once the perimeter is measured. With item 1 out of reach, a re-roof permit, the connector type in the attic and the openings carry these reports.

What usually decides it
Roof geometry, strap type and the re-roof paperwork
Have ready
The roofing permit and the HOA approval for any shutters or windows

Type03

55+ communities

Large age-restricted communities are a Palm Beach County signature, from Century Village in West Palm Beach to Kings Point near Delray Beach and the Valencia communities west of Boynton Beach. Some are condominiums, where the association owns the roof and most of the form describes the building. Others are single-family homes or villas under an HOA, where you own the roof but the association writes the rules for shutters and windows. Know which one you have before you book, because it changes what you can document and who has to approve an upgrade.

What usually decides it
Association roof records and the weakest window in the building
Have ready
Gate access, the manager's contact and the roof replacement year

Type04

Condo towers and mid-rise buildings

Coastal towers and mid-rises usually have concrete construction, flat or low-slope roofs and windows or shutters chosen by the association. For buildings with five or more units, the geometry item offers a flat roof answer when at least 90% of the main roof area has a slope under 2:12. Depending on the building, your insurer may want the uniform form or a building-level form, so ask your agent which one before anyone climbs to the roof.

What usually decides it
Building records, roof access and the openings across all units
Have ready
The association's roof and window documents

Type05

Manufactured homes

The county also has manufactured home parks, and those homes follow a different path. Citizens says its wind mitigation credits are not offered for mobile homes, and the wind standard a manufactured home was built to is shown by the HUD wind zone on its data plate rather than by the uniform form. Our guide to inspecting mobile and manufactured homes explains what insurers and buyers ask for instead.

What usually decides it
The insurer's own requirements for the home
Have ready
The data plate location and any tie-down or addition permits
Drone view of a mid-rise condo building with a flat roof full of A/C condensers and a terracotta barrel tile edge beside a waterway
Fig. 03Many condo roofs are flat behind a decorative tile edge. For buildings of five or more units, the form has a separate flat roof answer.

Condos, HOAs and 55+ communities: association records and board specifications

In much of Palm Beach County, the wind mitigation form depends on records you do not personally hold. A condo association keeps the roof permit, the re-roof contract and often the approvals for windows and shutters it installed. A homeowners' association keeps the architectural approvals for every shutter and window job in the community. Ask for those papers before the visit, not after the report comes back with unknowns.

What Florida law requires of condo boards

Under Section 718.113(5) of the Florida Statutes, each condominium's board has to adopt written hurricane protection specifications, building by building. Those specifications must meet the applicable building code and can set color, style and similar details. Putting in, maintaining or replacing hurricane protection under the subsection does not count as a material alteration of the common elements. And where the condo documents call for board approval, a board cannot turn down an owner who wants to install or replace protection that follows the adopted specifications, although it can insist on an existing unified look for the building.

The same subsection covers access and cost. A board may operate hurricane protection without the owner's permission only when that is necessary to protect the condominium or association property. Unless the declaration says otherwise, an owner does not pay to take down and put back hurricane protection when that work is needed to maintain or repair property the association is responsible for, and if the owner does that work, the association must reimburse the owner or credit the cost toward future assessments.

HOAs follow a parallel rule

For single-family homes and villas under a homeowners' association, Section 720.3035(6) works much the same way. The board or architectural committee must adopt hurricane protection specifications for each structure, in line with the building code, and it may not deny an application to install, enhance or replace hurricane protection that conforms to them. It can still require you to stay within an existing unified building scheme. The statute's definition is broad: roof systems recognized by the Florida Building Code that meet ASCE 7-22 standards, permanent fixed and roll-down storm shutters, impact-resistant windows and doors, polycarbonate panels, reinforced garage doors, erosion controls, exterior fixed generators and fuel storage tanks.

What to request from the association

  • The board's hurricane protection specifications, and your own approval letter for any shutter, window or door work.
  • The year the roof was replaced, the roofing permit and the roofer's paperwork, especially anything naming the underlayment.
  • Any building-level mitigation report the association ordered for its master policy.
  • Product approvals for windows, sliders and shutters the association installed.
  • Attic access arrangements, since in many low-rise buildings one attic runs over several units.

If you own a unit, much of the form is answered by the building rather than by you. Our article on condo insurance inspections for HO-6 policies sorts out which items belong to the owner, and a full condo unit inspection covers the condition of the unit itself when you are buying.

Two-story garden condo buildings in a 55+ community with open walkways, flat roofs, a lake and a mix of old and new windows
Fig. 04In a condo community, the roof and most openings belong to the building, so the association's records decide much of the form.

Wind mitigation and insurance in Palm Beach County: what the law and Citizens say

Start with what state law actually says. Section 627.712 requires an insurer that issues a residential property policy to provide windstorm coverage, with limited exceptions, and lets a policyholder exclude it only through a signed written statement. If the home is mortgaged, the owner also needs written approval from the mortgage holder before wind coverage can be dropped. Section 627.0629 then requires the mitigation credits, and since October 1, 2023, insurers have had to describe their hurricane mitigation discounts on their own websites. The amounts come from each insurer's rate filing, which is why two carriers can value the same report differently.

What Citizens publishes about its credits

Citizens Property Insurance, the state-created insurer, lists its discounts publicly. It says wind mitigation credits apply only to the wind portion of the premium and are not offered for mobile homes. Its Florida Building Code compliance discount generally applies to homes built on or after January 1, 2002, with a minimum FBC 2001 credit possible for older homes whose roofs were brought up to that code, and that particular discount does not apply to dwelling, rental, mobile home or condo policies. Citizens also lists an opening protection credit for properties of four or more stories built in 2002 or later, and it limits that one to Miami-Dade and Broward. If you own in a Palm Beach County building of that size, ask your agent how its openings are credited and expect them to need documentation.

On the 2026 form change, Citizens said inspections from April 1, 2026 use the new version, that it accepts the January 2012 form if it was completed within five years before that date with no changes to the structure, and that the new features do not change the credits it offers at this time. Private carriers set their own policies on older reports.

We never quote a savings figure, because we do not set the rates and every carrier files its own. What we can do is make sure every feature your house really has is on the form, with proof, so the credit your insurer applies matches the house you own.

Wind mitigation inspections in Boca Raton, Delray Beach, Boynton Beach and West Palm Beach

We serve Palm Beach County from our office in Hollywood, and four of its cities have their own pages with local detail: which office keeps the permits, what the housing looks like and the questions owners there ask most.

Elsewhere in the county, the inspection and the booking work the same way, and the list below links every city we cover with its own page.

Aerial view of waterfront homes with tile roofs on the Intracoastal and white condo towers on the barrier island in Palm Beach County
Fig. 05Near the coast, salt air ages straps and shutter hardware faster, and the form only credits connectors without visible severe corrosion.

Finding permits in Palm Beach County: city or county?

Items 1, 4 and 9 often turn on permit records, and in this county the first job is knowing which office has them. Palm Beach County has 39 incorporated municipalities, each with its own building department, while the county's Planning, Zoning and Building Department keeps the records for unincorporated land. A mailing address does not settle the question. Plenty of gated and 55+ communities carry a city's name on the envelope but sit outside any city limits.

Two quick checks help. The Palm Beach County Property Appraiser publishes a directory of municipal permit departments, and its parcel record shows your parcel control number (PCN). On the county's own search system, parcels whose PCN does not start with 00 belong to a municipality. The county's search services cover unincorporated property plus parcels a city later annexed from the county, and it asks you to check the annexation date first, because an annexed house can have its early permits with the county and its later ones with the city.

Where Palm Beach County records usually are, and which form items they support
DocumentWhere to lookForm items
Original building permit and its application dateThe city building department, or Palm Beach County Planning, Zoning and Building for unincorporated land1
Roofing permit, product approval and roofer's contractThe same office, your closing file or the roofer; the association for condo roofs4, 5 and 8
Window, door, shutter and garage door permitsCity or county permit history, or the contractor who did the work9
Florida Product Approval or Miami-Dade NOA numbersContracts, invoices, labels and the state and Miami-Dade approval lookups4 and 9
Year built and parcel control number (PCN)Palm Beach County Property AppraiserSpeeds up every permit search
Hurricane protection specifications and approval lettersThe condo board or HOA management9, and any planned upgrade
Strap retrofit paperwork or a FORTIFIED certificateThe installer or the certificate holder6, or items 4 to 6 and 8 to 9 with FORTIFIED

If a document cannot be found, tell us when you book. A product approval number on an old invoice, or a roofing contract that names the underlayment, is sometimes enough to turn an unknown into a documented answer.

How to prepare for a wind mitigation inspection in Palm Beach County

Most of the preparation is paperwork and access. Before the visit:

  • Confirm whether the home sits inside a city or in unincorporated Palm Beach County, then pull the permit history from the right office.
  • Find the roofing permit and any contract or invoice that lists product approval numbers, the nailing pattern or the underlayment.
  • Gather window, door, shutter and garage door permits with their Florida Product Approval or Miami-Dade NOA numbers.
  • Leave the labels on impact glass, and keep removable shutter panels and their hardware where they can be reached.
  • In a gated or 55+ community, put us on the gate list the day before and mention any visitor or parking rules.
  • In a condo, ask the manager about attic access, the roof records and the board's hurricane protection specifications.
  • Clear the path to the attic hatch, which in many homes here is in the garage ceiling or a bedroom closet.
  • If you spend part of the year up north, arrange for someone to let us in and sign the homeowner section of the form.
  • Have your last wind mitigation report and any FORTIFIED certificate on hand.

Most visits take under an hour. Large homes, tight attics and houses with many openings take longer, and the signed form usually arrives the same day.

Permit history printout, roofing contract, association approval letter and a gate pass laid out on a kitchen counter before an inspection
Fig. 06Permit histories, roofing contracts and association approvals often decide items 1, 4 and 9. Gather them before the visit.

Upgrades that move a Palm Beach County wind mitigation report

For a house permitted before 2002, upgrades are where most of the gains are. The form only credits work that is finished and documented, so plan the paperwork together with the project.

Openings

Protect every glazed opening, including sliders, the garage door and the small window in the guest bath, because one unprotected opening sets item 9 for the whole house. In a condo or HOA, get the specifications before you sign a contract. The statutes above give a conforming application a clear path.

Re-roofing

A re-roof is the one time the deck is exposed. It is the moment to add a sealed roof deck, renail the sheathing to a stronger pattern and put a new permit date on item 4. Ask the roofer to write the underlayment method and the nailing pattern into the contract. On an older tile roof, a roof inspection can tell you how much useful life is left before you decide.

Roof-to-wall retrofits

The 2026 form can credit purpose-made retrofit connectors by their tested uplift capacity when they are installed to the manufacturer's specifications with site-specific documentation. Get that documentation from the installer before work begins, not after.

State grants

The state's My Safe Florida Home grant program has offered free wind mitigation inspections and grants of up to $10,000 for qualifying improvements, but its funding and application windows change, so check mysafeflhome.com before planning around it.

After any of these projects, order a new inspection. The old report no longer describes the house, and it stays valid only while the structure is unchanged.

What older advice about Palm Beach wind mitigation got wrong

This page replaces an older article at the same address, and some of what it said, along with advice that still circulates online, needs correcting.

  • "Palm Beach homeowners must have windstorm insurance." The law puts the duty on insurers: Section 627.712 makes them provide windstorm coverage on residential policies, and an owner can exclude it only in writing. If there is a mortgage, the lender has a say, because it must approve any exclusion in writing.
  • "The inspector will recommend reinforcements." The inspection documents what exists. It is not a repair plan or an engineering evaluation, and the form itself says its definitions cannot certify any product or construction feature. We will tell you which answers an upgrade could change, but the decision is yours.
  • "It checks how the walls are tied to the foundation." The form does not ask about that connection. It covers the roof, the roof-to-wall connection and the openings, plus the building code, the region and the slope.
  • "Every Palm Beach home gets the same wind answers." Item 2 depends on the design wind speed at the address, and the county's own maps change with location and risk category. We look up each property.
  • "The inspection lowers your premium." It gives your insurer evidence. The credit, if any, comes from the insurer's filed rates, and every page of the form warns that some items may not qualify for a discount.
  • "A report done the Broward way works here." HVHZ answers, such as SFBC-94 on item 1, do not belong on a Palm Beach County form. A report that uses them should be corrected before it reaches your agent.

Before you send any report in, take a few minutes with our guide on how to check each answer on your report.

How much does a wind mitigation inspection cost in Palm Beach County?

The price depends on the size of the house, the number of roof sections and openings, attic access and whether you add a 4-point or a roof inspection to the same visit. We do not post a flat rate that might not fit your house. Call or text (954) 297-0317 with the address and the year built, seven days a week from 5 AM to 10 PM, and you will have a firm price before anything goes on the calendar.

Because the form can serve for up to five years while nothing about the structure changes, weigh the fee against several renewals, and ask your agent how your carrier credits the answers you expect to get.

The bottom line

A wind mitigation inspection in Palm Beach County uses the same nine-item form as the rest of Florida, but it reads differently here: no HVHZ answers, a Region looked up for each address, no 1994 code shortcut and a housing stock in which the roof, the attic and the openings usually carry the report. Associations hold many of the records, and Florida law gives owners a clear path to install hurricane protection that follows the board's specifications. If you want your home documented accurately, request a free quote or call (954) 297-0317. Peter Lemos, a Certified Master Inspector® and InterNACHI Certified Wind Mitigation Inspector, inspects homes across the county, gives you a firm price first and usually sends the signed form the same day. You can also read more about our wind mitigation inspections across South Florida.

Peter Lemos, Certified Master Inspector and owner of Global Home Inspectors

About the author

Peter Lemos, Certified Master Inspector®

Owner and lead inspector of Global Home Inspectors in Hollywood, FL. Peter holds InterNACHI certifications in wind mitigation, 4-point and mold inspection and has served Broward, Miami-Dade and Palm Beach counties since 2008, with more than 7,000 inspections completed.

Good questions

Palm Beach County Wind Mitigation FAQs

Short answers to what Palm Beach County owners ask most. Don't see yours? Call or text (954) 297-0317.

Is Palm Beach County in the High-Velocity Hurricane Zone?

No. The Florida Building Code limits the HVHZ to Broward and Miami-Dade. Palm Beach County follows the statewide wind provisions, so its wind mitigation forms never answer HVHZ on the region item and never use the 1994 South Florida code option.

What wind region is my Palm Beach County home in?

It depends on the exact address. We look up the design wind speed in the ASCE 7-22 hazard tool and mark Region 1, 2 or 3 to match. Homes a few miles apart can answer differently, so a neighbor's report is not a reliable guide.

Do I need a wind mitigation inspection to insure a home in Palm Beach County?

No law requires one. Insurers must offer credits for qualifying features, and the form is how you prove you have them. Many owners order it when they buy, at renewal or right after a new roof or new windows.

How long does the inspection take, and when do I get the report?

Most homes take under an hour, with larger houses and cramped attics taking longer. The signed form and its photos usually arrive the same day, and you forward them to your insurance agent.

Can my condo board refuse to let me install hurricane shutters?

Where your condo documents require approval, the board may not refuse protection that follows the specifications it adopted under Section 718.113(5), although it can require a consistent look. Get those specifications in writing before you order anything.

Does my HOA have to approve impact windows?

Your HOA can require an application, but under Section 720.3035(6) it may not deny one that conforms to its adopted hurricane protection specifications. It can still require that the products fit an existing unified building scheme.

My home was built in the 1990s. Can it still earn credits?

Yes, it can. The building code item will not apply to a home permitted before March 1, 2002, but roof shape, deck nailing, roof-to-wall connectors, a sealed roof deck and protected openings are each documented on their own. Your insurer decides what each answer is worth.

Where do I find the permits for my house?

Inside a city, ask that city's building department. For unincorporated areas, Palm Beach County Planning, Zoning and Building keeps the records. The Property Appraiser lists every municipal permit office, and your parcel control number speeds up any search.

Does Citizens give wind mitigation credits on mobile homes?

Citizens says its wind mitigation credits are not offered for mobile homes. Other insurers set their own rules, so ask your agent which inspection your carrier wants for a manufactured home before you book anything.

South Florida home with a pool and lanai lit at night

Free estimate

Schedule a Wind Mitigation Inspection in Palm Beach County

Call or text for the fastest response. We answer seven days a week and can often inspect the same or next day.

Call or text(954) 297-0317 Emailglobalhomeinspectors@gmail.com
HoursMon – Sun · 5:00 AM – 10:00 PM
We speakEnglish · Português · Español

Inspection work order

Nº GHI-0000
Best way to reach you
Best time
Preferred language

Prefer to talk? Call or text (954) 297-0317. By sending, you agree to our Privacy Policy.